Services
Double Check Valve assembly (DCVA)
The DCVA is used in low hazard applications for backsiphonage protection. These assemblies are commonly found on carbonated beverage machines or dispensers and residential boilers, when there are no additions of chemicals to the boiler. The carbonated beverage DCVA specification is ASSE 1022. The boiler DCVA specification is ASSE 1015. These assemblies are repairable and are required to be annually tested and certified.
Reduced Pressure Principal Assembly
The RPPA is used in low and high hazard applications for protection from backsiphonage and backpressure. These assemblies are commonly found on commercial water taps and at individual points of use. The RPPA specification is ASSE 1013. These assemblies are repairable and are required to be annually tested and certified.
Pressure Vacuum Breaker Assembly
The Pressure Vacuum Breaker Assembly is the most commonly used backflow prevention assembly and is recognizable to most homeowners and commercial irrigators as it is found on every residential underground lawn sprinkler and irrigation systems. The PVBA specification is ASSE 1020 and is designed for low or high hazard applications for protection against backsiphonage. These assemblies are repairable, if necessary and are required to be annually tested and certified.
Spill Resistant Pressure Vacuum Breaker Assembly
The Spill Resistant Pressure Vacuum Breaker Assembly is similar to the PVBA, but is newer and is designed for indoor applications. The SRPVB specification is ASSE 1056 and is designed for low and high hazard applications for protection against backsiphonage. Annual testing and certification is required for these repairable assemblies.
Atmospheric Vacuum Breaker
The Atmospheric Vacuum Breaker is an early design of the vacuum breaker, first patented in the 1860’s. The AVB specification is ASSE 1001 and is designed for low or high hazard applications for protection against backsiphonage. This device is not testable, is not required to be annually certified and is not repairable.
Hose Bib (faucet) Vacuum Breakers and Backflow Preventers
The Hose Bib Vacuum Breaker (freeze resistant), ASSE specification 1019, is very common in areas such as Colorado where freezing temperatures are present in the winter. These devices are not required to be annually tested and certified. The Hose Connection Backflow Preventer, ASSE specification 1052 is commonly found in regions that do not experience freezing temperatures. These devices are designed for low and high hazard protection from backsiphonage, they are testable but, annual certification of these devices is not required.
We provide backflow testing and certification services in Arapahoe, Denver, Douglas, El Paso, Grand, Pueblo, Routt and Summit Counties.
F.A.Q.
As the owner of a single family residence, you are not yet required to test your backflow preventer assembly. However, since you have no way to determine whether or not your backflow preventer is working properly, it is recommended to have it tested. As a service to the public, we offer a steep discount on testing for homeowners. Please contact us soon for an appointment!
You are required to have an annual test and certification of your backflow prevention assembly each year, prior to the date set by your water provider. Please contact us for an appointment for testing!
You are required to have an annual testing and certification of your backflow prevention assemblies. Your water provider will send you a notice prior to the certification expiring. Please contact us for an appointment for a new test and certification!
If each unit’s owner receives a water bill directly from the provider, you are not required to have an annual certification. However, if your association has a common area irrigation system, you are required to have your backflow prevention assemblies tested and certified each year, prior to the date of compliance. Please call soon for an appointment to stay in compliance!
Duplexes, like single family residences, are currently exempt from annual backflow preventer testing and certification. However, as in single family residences, we offer, as a public service, steeply discounted testing to assure you that your assemblies are working properly.
We offer a complete solution for compliance with the Safe Drinking Water Act of 1974. Our services include performing sanitary surveys of individual facilities or businesses in your district. We also have compliance questionnaires to send to your customers for voluntary surveys. We can track and manage your entire backflow program, including filing all the necessary documents with the State office or, with your water provider, if you are a reseller of water from another entity.